Analysis on the Causes of Rotational Indexing and Positionin

2021-08-20 09:36   camdex indexer      
In the use of rotary indexing table, there are more and more application cases for disc transmission. For multi-station transmission, the guarantee of repeated positioning accuracy is a factor reflecting the quality of the indexer. It is used in the initial use and a certain period of use. Later, there will be an offset of the indexer disc angle. Today, the editor will make a detailed analysis of the indexer angle offset for everyone.
Cam indexing table,Index locator,Cam index drive
The so-called offset of the indexer angle refers to the difference between the indexer's rotation angle due to various factors and the expected rotation angle. Of course, based on the repeatability of the indexer, it has reached a relatively high accuracy, ± 30arc-sec is a relatively small unit of radian. Even in this case, there will be an angular deviation in the intermittent stay, but the deviation range is within the allowable range. Then, when the deviation is too large and exceeds the use range of the disk rotation, the entire drive system needs to be reconfirmed and debugged.
Cam indexing table,Index locator,Cam index drive
The deviation caused by the use of the rotary indexing table is analyzed from two aspects:
1. The deviation of the automatic drive system after debugging after it has not been put into use. First of all, the reason we said needs to be excluded from the indexer itself. 1. The signal cam installation angle of the rotary indexing table is offset, that is The drive angle of the input cam of the indexer and the drive angle of the signal cam are not in the same position; 2. The drive angle of the signal cam is selected incorrectly, that is, when the drive angle of the indexer is 270 degrees, the signal cam chooses 240 degrees, etc. Other angles. 3. The installation screw of the indexer output shaft and the drive disc is loose; 4. The installation angle of the disc and the rotation angle of the indexer are offset; 4. The signal cam device is installed loose; 5. The induction switch caused by current and other reasons Signal transmission is abnormal.
2. Another reason is that after the indexer has been used for a period of time, the deviation of the rotation angle between the disc and the indexer appears. The reason mentioned here is the same as the previous reason. The offset size has exceeded the repeat positioning accuracy. Outside the allowable range, it has affected the processing of the workpiece. 1. The internal components of the rotary indexing table are worn and angular deviation; 2. The screw at the connection between the disc and the indexer is loose; 3. The signal cam of the indexer or The induction switch is offset; 4. The signal influence of the induction switch of the indexer.
Cam indexing table,Index locator,Cam index drive
The above is an analysis of the reasons for the angular deviation of the driving disc of the rotary indexing table. Then, what should be done to deal with the above situation?
1. For the induction drive system of the rotary indexing table, the photoelectric sensor switch and signal cam are mainly used. When the photoelectric sensor switch is normal, the installation of the signal cam is particularly important. Normally, the signal cam is installed correctly. The method is to align the keyway of the input shaft of the indexer with the keyway of the signal cam; in addition, another installation method is to install the keyway of the input shaft of the indexer and the keyway of the signal cam diagonally;
2. The angle selection of the signal cam is inconsistent with the driving angle of the indexer input shaft. The driving angle of the input shaft is specific, while the angle of the signal cam is installed on the outside of the indexer. Therefore, when installing the signal cam, use measurement After the tool measures the driving angle, install it;
3. The installation screws of the output shaft or flange surface of the rotary indexing table and the disc are loose, and there are many installation screws of the indexer, and all installation parts need to be regularly inspected and firm;
4. The signal cam and induction switch should also be inspected regularly to see if the installation position is loose;
5. The influence of the current of the induction switch on the signal transmission needs to be measured by an electrician using a professional measuring instrument, and abnormal conditions need to be repaired and modified;
6. For the indexer that uses a certain period, after confirming the above items, there is still a slight offset, and it is necessary to check and confirm the wear of the internal mechanism of the indexer.
In short, the angle deviation of the indexer is one of the common faults in use. Most of the cases are caused by improper measures adopted in the later installation and debugging process. Therefore, as engineers and technicians, we must combine the actual conditions of mechanical operation. , Analyze the reasons for the offset, and then take corresponding countermeasures.